CVE-2026-126978
High 8.8No known exploitationFix status unknownPhilips Hue Bridge hap_pair_setup_handler Heap-based Buffer Overflow Remote Code Execution Vulnerability
Record last updated
CVSS score
High on a 0 to 10 scale
EPSS, chance of exploitation in 30 days
Higher than 42% of scored CVEs. A prediction, not evidence.
CISA remediation deadline
Not in the KEV catalog
Description
Philips Hue Bridge hap_pair_setup_handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. When parsing pairing requests, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length, heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28434.
Weakness: CWE-122
Patching and mitigation
- Patch status
- Unknown: no source documents a fix
- Mitigation
- None documented
- Vendor guidance
- No vendor link on record
Affected products
| Vendor | Product | Affected versions | Fixed in | Per |
|---|---|---|---|---|
| Philips | Hue Bridge | 1.73.1973146020 | Not documented | CVE Program |
Timeline
Disclosure
CVE record published by zdi
Source: CVE Program (opens in a new tab)
Vendor guidance and references
- ZDI-26-963 (opens in a new tab)x_research-advisory