Skip to content
Threat Brief

← All advisories

CVE-2026-111215

High 8.6No known exploitationFix available

Netgate pfSense CE through 2.9.0 and Plus through 26.07 OS Command Injection via Wireless Parent Interface

Record last updated

CVSS score

8.6

High on a 0 to 10 scale

EPSS, chance of exploitation in 30 days

7.5%

Higher than 95% of scored CVEs. A prediction, not evidence.

CISA remediation deadline

None

Not in the KEV catalog

Description

Netgate pfSense CE through 2.9.0 and Plus through 26.07 contains an OS command injection vulnerability that allows authenticated users to execute commands as root by supplying a crafted wireless parent interface name. Attackers with limited Wireless Edit or Interface Assignments privileges can submit values like ath0; via interfaces_wireless_edit.php or interfaces_assign.php, which interface_wireless_clone() interpolates unescaped into an ifconfig shell command.

Weakness: CWE-78

Patching and mitigation

Patch status
Fix available (source: CVE record (VulnCheck))
Fix documented (source date)
Mitigation
None documented
Vendor guidance
docs.netgate.com (opens in a new tab)

Affected products

VendorProductAffected versionsFixed inPer
NetgatepfSense CEall versions before 2.9.12.9.1CVE Program
NetgatepfSense Plusall versions before 26.07.126.07.1CVE Program
pfsensepfsenseall versions up to and including 2.9.0Not documentedNIST NVD

Timeline

  1. Disclosure

    CVE record published by VulnCheck

    Source: CVE Program (opens in a new tab)

  2. Patch

    Fix documented by CVE record (VulnCheck)

    Source: CVE record (VulnCheck) (opens in a new tab)

Vendor guidance and references