CVE-2017-6884
High 8.8KEV · exploitedPublic exploitFix status unknownZyxel EMG2926 Routers Command Injection Vulnerability
Record last updated
CVSS score
High on a 0 to 10 scale
EPSS, chance of exploitation in 30 days
Higher than 98% of scored CVEs. A prediction, not evidence.
CISA remediation deadline
Passed 1139 days ago for U.S. federal agencies
Description
A command injection vulnerability was discovered on the Zyxel EMG2926 home router with firmware V1.00(AAQT.4)b8. The vulnerability is located in the diagnostic tools, specifically the nslookup function. A malicious user may exploit numerous vectors to execute arbitrary commands on the router, such as the ping_ip parameter to the expert/maintenance/diagnostic/nslookup URI.
Weakness: CWE-78
Patching and mitigation
- Patch status
- Unknown: no source documents a fix
- Mitigation
- None documented
- Vendor guidance
- zyxel.com (opens in a new tab)
Affected products
| Vendor | Product | Affected versions | Fixed in | Per |
|---|---|---|---|---|
| Zyxel | EMG2926 Routers | Not documented | Not documented | CISA KEV |
Timeline
Disclosure
CVE record published by mitre
Source: CVE Program (opens in a new tab)
18 Sep 2023KEV
Added to the CISA Known Exploited Vulnerabilities catalog
Source: CISA KEV (opens in a new tab)
18 Sep 2023Exploitation
Exploitation confirmed by CISA KEV
Source: CISA KEV (opens in a new tab)
Vendor guidance and references
- https://www.zyxel.com/global/en/support/security-advisories/zyxel-security-advisory-for-command-injection-vulnerability-in-emg2926-q10a-ethernet-cpe, (opens in a new tab)vendor-advisory
- https://www.zyxelguard.com/Zyxel-EOL.asp (opens in a new tab)vendor-advisory
- https://nvd.nist.gov/vuln/detail/CVE-2017-6884 (opens in a new tab)government
- https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2017-6884 (opens in a new tab)government-resource
Public exploit code
Exploit or proof-of-concept code is publicly available on Exploit-DB. Shown as a prioritization and defensive-testing signal — treat exploit code as hostile and run it only against systems you are authorized to test.